Device uses 7 (known) fuses within range 34134..34170 for global feature and JTAG configuration.
| 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | |
| 34134 | A | IO | M | M | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | C | ? | ? | ? | ? | ? | ? |
| 34166 | C | M | ? | ? |
Fuse combinations for option "arming_switch":
34134 | |
|---|---|
| safe | 1 |
| armed | 0 |
Fuse combinations for option "read_protection":
34166 | |
|---|---|
| on | 0 |
| off | 1 |
Fuse combinations for option "jtag_pin_func":
34167 | |
|---|---|
| jtag | 1 |
| user | 0 |
Fuse combinations for option "pd1_pin_func":
34136 | |
|---|---|
| pd | 0 |
| user | 1 |
Fuse combinations for option "pd2_pin_func":
34137 | |
|---|---|
| pd | 0 |
| user | 1 |
Fuse combinations for option "termination":
34135 | |
|---|---|
| bus_keeper | 0 |
| high_z | 1 |
Fuse combinations for option "reset_hysteresis":
34159 | |
|---|---|
| large | 0 |
| small | 1 |