Most pins are configured through the associated macrocells. This page describes configuration of dedicated inputs and pins configured to have a special function.
Device uses 14 (known) fuses within range 16750..16790 for configuring pins TMS, TDI, CLK1, CLK2, OE1, CLR.
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | |
16750 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | IO | IO | IO | IO | IO | IO | IO | IO | IO | IO | IO | IO | IO | IO | ? |
16782 | ? | - | - | - | ? | ? | ? | ? |
Pin TMS uses the following 1 (known) fuses for configuration.
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | |
16750 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | IO | - | - | - | - | - | - | - | - | - | - | - | - | - | ? |
Fuse combinations for option "termination":
16767 | |
---|---|
high_z | 1 |
pull_up | 0 |
Pin TDI uses the following 1 (known) fuses for configuration.
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | |
16750 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | IO | - | - | - | - | - | - | - | - | - | - | - | - | ? |
Fuse combinations for option "termination":
16768 | |
---|---|
high_z | 1 |
pull_up | 0 |
Pin CLK1 uses the following 3 (known) fuses for configuration.
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | |
16750 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | IO | - | - | - | IO | IO | - | - | - | - | - | - | ? |
Fuse combinations for option "termination":
16773 | 16774 | |
---|---|---|
bus_keeper | 1 | 1 |
high_z | 0 | 0 |
pull_down | 1 | 0 |
pull_up | 0 | 1 |
Fuse combinations for option "hysteresis":
16769 | |
---|---|
off | 1 |
on | 0 |
Pin CLK2 uses the following 3 (known) fuses for configuration.
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | |
16750 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | IO | - | - | - | - | IO | IO | - | - | - | - | ? |
Fuse combinations for option "termination":
16775 | 16776 | |
---|---|---|
bus_keeper | 1 | 1 |
high_z | 0 | 0 |
pull_down | 1 | 0 |
pull_up | 0 | 1 |
Fuse combinations for option "hysteresis":
16770 | |
---|---|
off | 1 |
on | 0 |
Pin OE1 uses the following 3 (known) fuses for configuration.
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | |
16750 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | IO | - | - | - | - | - | IO | IO | - | - | ? |
Fuse combinations for option "termination":
16777 | 16778 | |
---|---|---|
bus_keeper | 1 | 1 |
high_z | 0 | 0 |
pull_down | 1 | 0 |
pull_up | 0 | 1 |
Fuse combinations for option "hysteresis":
16771 | |
---|---|
off | 1 |
on | 0 |
Pin CLR uses the following 3 (known) fuses for configuration.
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | |
16750 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | IO | - | - | - | - | - | - | IO | IO | ? |
Fuse combinations for option "termination":
16779 | 16780 | |
---|---|---|
bus_keeper | 1 | 1 |
high_z | 0 | 0 |
pull_down | 1 | 0 |
pull_up | 0 | 1 |
Fuse combinations for option "hysteresis":
16772 | |
---|---|
off | 1 |
on | 0 |